Influences of Topical Cyclopentolate on Anterior Chamber Parameters With a Dual-Scheimpflug Analyzer in Healthy Children

dc.contributor.authorGuler, Emre
dc.contributor.authorGuragac, Fatma Betul
dc.contributor.authorTenlik, Aylin
dc.contributor.authorYagci, Ramazan
dc.contributor.authorArslanyilmaz, Zeynel
dc.contributor.authorBalci, Mehmet
dc.date.accessioned2025-10-24T18:09:57Z
dc.date.available2025-10-24T18:09:57Z
dc.date.issued2015
dc.departmentMalatya Turgut Özal Üniversitesi
dc.description.abstractPurpose: To evaluate the changes of anterior segment parameters following the topical instillation of cyclopentolate hydrochloride 1% with the Galilei dual-Scheimpflug analyzer (GSA) (Ziemer Ophthalmology Co., Port, Switzerland) in healthy children. Methods: Fifty children (29 boys, 21 girls) were evaluated before and 60 minutes after instillation of three drops of 1% cyclopentolate hydrochloride using the GSA. The measurements before and after cycloplegia, including anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), and pupil size, were evaluated using the paired t test. Results: The mean age of the patients was 10.27 +/- 3.32 years (range: 5 to 15 years). Measurements between the two sessions were significantly different for all parameters (P < .05), except for CCT (P > .05). Conclusions: The GSA demonstrated a statistically significant increase in ACD, ACV, ACA, and pupil size following the topical application of cyclopentolate hydrochloride 1%. These results should be considered during biometric measurement and refractive surgery planning.
dc.identifier.doi10.3928/01913913-20141111-02
dc.identifier.endpage30
dc.identifier.issn0191-3913
dc.identifier.issn1938-2405
dc.identifier.issue1
dc.identifier.pmid25403030
dc.identifier.scopus2-s2.0-84928190734
dc.identifier.scopusqualityQ3
dc.identifier.startpage26
dc.identifier.urihttps://doi.org/10.3928/01913913-20141111-02
dc.identifier.urihttps://hdl.handle.net/20.500.12899/3884
dc.identifier.volume52
dc.identifier.wosWOS:000351639500008
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSlack Inc
dc.relation.ispartofJournal Of Pediatric Ophthalmology & Strabismus
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_20251023
dc.subjectIntraocular-Lens Implantation; Refractive Surgery; Power Calculations; Corneal Thickness; Repeatability; Readings; Biometry; Depth; Laser
dc.titleInfluences of Topical Cyclopentolate on Anterior Chamber Parameters With a Dual-Scheimpflug Analyzer in Healthy Children
dc.typeArticle

Dosyalar