Influences of Topical Cyclopentolate on Anterior Chamber Parameters With a Dual-Scheimpflug Analyzer in Healthy Children
Küçük Resim Yok
Tarih
2015
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Slack Inc
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Purpose: To evaluate the changes of anterior segment parameters following the topical instillation of cyclopentolate hydrochloride 1% with the Galilei dual-Scheimpflug analyzer (GSA) (Ziemer Ophthalmology Co., Port, Switzerland) in healthy children. Methods: Fifty children (29 boys, 21 girls) were evaluated before and 60 minutes after instillation of three drops of 1% cyclopentolate hydrochloride using the GSA. The measurements before and after cycloplegia, including anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), and pupil size, were evaluated using the paired t test. Results: The mean age of the patients was 10.27 +/- 3.32 years (range: 5 to 15 years). Measurements between the two sessions were significantly different for all parameters (P < .05), except for CCT (P > .05). Conclusions: The GSA demonstrated a statistically significant increase in ACD, ACV, ACA, and pupil size following the topical application of cyclopentolate hydrochloride 1%. These results should be considered during biometric measurement and refractive surgery planning.
Açıklama
Anahtar Kelimeler
Intraocular-Lens Implantation; Refractive Surgery; Power Calculations; Corneal Thickness; Repeatability; Readings; Biometry; Depth; Laser
Kaynak
Journal Of Pediatric Ophthalmology & Strabismus
WoS Q Değeri
Q3
Scopus Q Değeri
Q3
Cilt
52
Sayı
1












