Does the wedge wing in the neck screw prevent cut-out failure in OTA/AO 31- A2 trochanteric fractures in elderly patients?
| dc.contributor.author | Günay, Cüneyd | |
| dc.contributor.author | Atalar, Hakan | |
| dc.contributor.author | Altay, Murat | |
| dc.contributor.author | Yavuz, Osman Yüksel | |
| dc.contributor.author | Yildirim, Ahmet Özgür | |
| dc.contributor.author | Öken, Fuad O. | |
| dc.date.accessioned | 2025-10-24T18:06:51Z | |
| dc.date.available | 2025-10-24T18:06:51Z | |
| dc.date.issued | 2014 | |
| dc.department | Malatya Turgut Özal Üniversitesi | |
| dc.description.abstract | The purpose of this retrospective study was to evaluate the effects of Dyna Locking Trochanteric (DLT) nail (U & I Corporation 529-1, Yonghyun-dong, Uijungbu Kyunggi-Do, Korea 480-050) in 31-A1 and 31-A2 intertrochanteric femur fractures. Eightyseven patients (63 female and 24 male, mean age 77 years) were treated. The mean duration of followup was 16.6 ± 3.1 months (range, 12-24 months). There were 36 cases of 31-A1 and 51 cases of 31-A2 fractures. The duration of surgery, fluoroscopy screening time, the blood loss, the hospital stay, the tip-apex distance were significantly less in the 31-A1 fracture group compared with the 31-A2 fracture group (p < 0.001). Cut-out was observed in 13 patients (14.9%) above 80 years old with 31-A2 fractures. Especially in elderly patients with unstable 31-A2 fractures, the wedge wing on the neck screw does not work properly. Therefore further biomechanical investigations and also prospective clinical studies with larger series are needed to improve the device. © 2014, Acta Orthopdica Belgica. © 2014 Elsevier B.V., All rights reserved. | |
| dc.identifier.endpage | 33 | |
| dc.identifier.issn | 0001-6462 | |
| dc.identifier.issue | 1 | |
| dc.identifier.pmid | 24873081 | |
| dc.identifier.scopus | 2-s2.0-84901438570 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 26 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12899/3231 | |
| dc.identifier.volume | 80 | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | ARSMB-KVBMG aob.edit@skynet.be). amb@skynet.be Avenue W. Churchill-laan 11/30 Brussels B-1180 | |
| dc.relation.ispartof | Acta Orthopaedica Belgica | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | Scopus_20251023 | |
| dc.subject | Complication | |
| dc.subject | Cutting out | |
| dc.subject | Intertrochanteric fractures | |
| dc.subject | Intramedullary nailing | |
| dc.subject | Outcomes | |
| dc.subject | Tip apex distance | |
| dc.title | Does the wedge wing in the neck screw prevent cut-out failure in OTA/AO 31- A2 trochanteric fractures in elderly patients? | |
| dc.type | Review Article |