The Effectiveness Of The Ambu® Auragain™ Laryngeal Mask On Hemodynamic And Respiratory Parameters İn Patients Undergoing Septoplasty: A Randomized Prospective Clinical Study

dc.authorid0000-0003-1025-7662en_US
dc.contributor.authorÖterkuş, Mesut
dc.contributor.authorSelçuk Kuşderci, Hatice
dc.date.accessioned2022-03-16T21:32:22Z
dc.date.available2022-03-16T21:32:22Z
dc.date.issued2021-08-28en_US
dc.departmentMTÖ Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractBackground/Aim: The use of laryngeal masks is increasing with the introduction of 3rd generation airway vehicles. However, endotracheal intubation is preferred by most anesthesiologists in septoplasty operations due to airway safety concerns. In this study, we aimed to compare the 3rd generation airway device, Ambu® Auragain ™ LMA, with tracheal intubation in terms of hemodynamic and respiratory parameters. Methods: This study included 69 patients aged 18–60 years with an ASA score of 1–2 who were scheduled for septoplasty in Adıyaman University Research and Educational Hospital between 2016.01.01 and 2017.06.31. Study groups were randomly defined as Group 1 - Ambu® AuraGain™ laryngeal mask (LMA, n = 37) and Group 2 - endotracheal intubation (ETT, n = 32), and the hemodynamic and respiratory parameters were measured and recorded. Results: The demographic data and partial oxygen saturation of the patients were similar (P>0.05 for all values). The patients in the ETT group had a higher heart rate at induction, intubation and at the first minute compared to the LMA group (P<0.05 for all values). The mean arterial pressure was significantly lower at induction, intubation, at minutes 1, 2, 3, and 4 of intubation, and at extubation in the LMA group (P<0.05 for all values). Conclusion: The Ambu® AuraGain™ laryngeal mask was similar to or better than tracheal intubation in terms of hemodynamic and respiratory parameters. The Ambu® AuraGain™ LMA can be used as an equivalent to tracheal intubation in terms of hemodynamic and respiratory parameters.en_US
dc.identifier.citationÖterkuş, M., & Kuşderci, H. S. (2021). The effectiveness of the Ambu® AuraGain™ laryngeal mask on hemodynamic and respiratory parameters in patients undergoing septoplasty: A randomized prospective clinical study. J Surg Med, 5, 772-6.en_US
dc.identifier.doi10.28982/josam.951382
dc.identifier.endpage776en_US
dc.identifier.issue8en_US
dc.identifier.startpage772en_US
dc.identifier.urihttp://jsurgmed.com/tr/download/article-file/1820129
dc.identifier.uri10.28982/josam.951382
dc.identifier.urihttps://hdl.handle.net/20.500.12899/670
dc.identifier.volume5en_US
dc.institutionauthorÖterkuş, Mesut
dc.language.isoenen_US
dc.relation.ispartofJournal of Surgery and Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası - Editör Denetimli Dergien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAmbu® AuraGain™ Laryngeal Masken_US
dc.subjectTracheal İntubationen_US
dc.subjectSeptoplastyen_US
dc.titleThe Effectiveness Of The Ambu® Auragain™ Laryngeal Mask On Hemodynamic And Respiratory Parameters İn Patients Undergoing Septoplasty: A Randomized Prospective Clinical Studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
10.28982-josam.951382-1820129.pdf
Boyut:
588.91 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: