Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Novruzov, Zaur" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Turkish Norms of McNamara's Cephalometric Analysis
    (Aves Press Ltd, 2014) Aydemir, Halise; Novruzov, Zaur; Toygar-Memikoglu, Ufuk
    Objective: (1) To establish cephalometric standards for the Turkish adult population, (2) to compare Turkish norms with the published standards of McNamara norms, and (3) to compare the assessment of craniofacial structure by extracranial and intracranial reference lines. Materials and Method: The main study sample consisted of 44 female and 29 male dental students aged between 19 and 29 years. All of the head films were taken in the natural head position, which was determined with 0.5-mm wire that was attached to a fluid level device to represent the true horizontal and a metal chain that was suspended in front of the cassette to check the true horizontal. Results: For men, N perp A and Pg N perp were significantly greater (p < 0.001) in the Turkish population, whereas SNA (p < 0.001), CoGn (p < 0.001), CoA (p < 0.001), upper incisal A vertical (p < 0.05), and lower incisor A pg (p < 0.05) were significantly smaller. In women, N perp A and Pg N perp were significantly greater (p < 0.001) in the Turkish population, whereas SNA (p < 0.01), CoGn (p < 0.001), and CoA (p < 0.01) were significantly smaller. For both men and women, only the variables FH/GoMe and X1-X2/GoMe were compatible with each other (p < 0.001). Conclusion: The Anotolian Turkish sample has shorter midfacial (Co-A) and mandibular (Co-Gn) lengths and a more protrusive maxilla (N perp A) and mandible (Pg N perp). Extracranial reference lines are more reliable than intracranial reference lines because of interindividual variability.

| Malatya Turgut Özal Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Malatya Turgut Özal Üniversitesi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim