Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorCanpolat, Özgür
dc.contributor.authorVarol, Memet
dc.contributor.authorÖztekin Okan, Özlem
dc.contributor.authorEriş, Kürşad Kadir
dc.contributor.authorÇağlar, Metin
dc.date.accessioned2021-09-17T20:50:40Z
dc.date.available2021-09-17T20:50:40Z
dc.date.issued2020en_US
dc.identifier.citationCanpolat, Ö., Varol, M., Okan, Ö. Ö., Eriş, K. K., & Çağlar, M. (2020). A comparison of trace element concentrations in surface and deep water of the Keban Dam Lake (Turkey) and associated health risk assessment. Environmental Research, 190, 110012.en_US
dc.identifier.issn0013-9351en_US
dc.identifier.issn1096-0953en_US
dc.identifier.urihttps://doi.org/10.1016/j.envres.2020.110012
dc.identifier.urihttps://hdl.handle.net/20.500.12899/427
dc.description.abstractKeban Dam Lake (KDL) is the second largest dam lake in Turkey. There have been some reports on the trace element (TE) levels in surface water of the KDL, but its deep water has been never studied. We measured 17 TEs (Pb, Hg, Cd, As, Cr, Ni, Co, Mn, Cu, Fe, Al, Sr, U, V, Zn, Zr and Ba) in surface and deep water samples and assessed their health risks for residential and recreational receptors. Copper, Zn, Ba, Ni, Mn and Pb levels in deep water were higher than those in surface water. Total TE level in deep water was higher in wet season, whereas that in surface water was higher in dry season. TE levels in both surface and deep water were much lower than the guideline values for drinking water and the protection of freshwater aquatic life, indicating that TEs in the KDL originate from natural sources. All HQ (hazard quotient) and HI (hazard index) values were below the risk threshold of unity. HI values for child were higher than those for adult, indicating that the health of children is at dramatically higher risk than adults. Arsenic and U for water ingestion were the primary contributors to total risk (HI), while V and Cr for dermal pathway. The presence of U and V, among the TEs which are major contributors to total health risk, reveals the necessity of monitoring of such less-studied elements in the surface water bodies. Carcinogenic risk values of As and Cr in surface and deep water were below the target risk of 1 × 10−4. These findings indicated that TEs in surface and deep water of the KDL do not pose health risks to residential and recreational users. Thus this study may serve as a model for similar studies assessing health risks of multi-elements in freshwater bodies in future.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofEnvironmental Researchen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectTrace elementsen_US
dc.subjectDam lakeen_US
dc.subjectSurface and deep wateren_US
dc.subjectRisk assessmenten_US
dc.titleA comparison of trace element concentrations in surface and deep water of the Keban Dam Lake (Turkey) and associated health risk assessmenten_US
dc.typeArticleen_US
dc.authorid0000-0001-6475-0570en_US
dc.departmentMTÖ Üniversitesi, Doğanşehir Vahap Küçük Meslek Yüksekokulu, Su Ürünleri Bölümüen_US
dc.institutionauthorVarol, Memet
dc.identifier.doi10.1016/j.envres.2020.110012
dc.identifier.volume190en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid32763277
dc.identifier.scopus2-s2.0-85089190795en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.wosWOS:000576671000004en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster